7.6. DTE-DCE character framing +ICF
This command is used to determine the local serial port start-stop
(asynchronous) character framing that the DCE shall use.
AT+ICF=<format>,<parity>
* <format> :
0 autodetect not supported
1 8 Data 2 Stop supported
2 8 Data 1 Parity 1 Stop supported
3 8 Data 1 Stop supported
4 7 Data 2 Stop supported
5 7 Data 1 Parity 1 Stop supported
6 7 Data 1 Stop supported
* <parity> :
0 Odd supported
1 Even supported
2 Mark supported
3 Space supported
4 None supported
Application to GSM AT+ICF?
GSM to application +ICF: 3,4
OK
current values
Application to GSM AT+ICF=?
GSM to application +ICF: (0-6),(0-3)
OK
possible values.
Application to GSM AT+ICF=0,0
GSM to application OK new values
7.7. Repeat last command A/
Application to GSM A/ repeat last command